Now it’s time for the timer. When the switch is turned on, I want the pump to run for a couple of seconds and then turn off automatically. I want this behavior to prevent my balcony from getting flooded. In technical terms what I need is an edge triggered, non retriggerable monostable mutivibrator… aka – a timer. I was looking a bit at modern equivalents of the 74LS121, but they are a bit hard to find and they cannot drive very much current. So in the end I fell for the good old NE555. I guess a digital boy would have gone for a PIC-processor, but I am old school. I also know the NE555 is totally outdated, but it is easy to work with, easy to find and the output stage packs enough punch to drive a relay directly. I will be paying a price in form of high power consumption, but I had one lying around, so I took that. The NE555 can easily be connected as a monoflop, but it is not edge triggered so I have to fix that externally. The circuit I ended up with is shown below:
C1, R6 and R2 form the timing RC-circuit. It gives a max time around 7 seconds. D2 is a bit special, I read that it is needed to avoid the spike from the relay retriggering the circuit. I did not actually mount it on my board (I forgot it), but I put it in now when I made the schematic.
R3, C2, R4 makes the input edge triggered, as only flanks pass the capacitor.
I tried connecting the output from the receiver (the slaughtered spotlight) directly to the input, but the flank was not high enough, so I had to add R5, Q1 to amplify the signal. Below is the circuit tested on an experiment board.
Showing posts with label blombevattning. Show all posts
Showing posts with label blombevattning. Show all posts
2012-06-13
Subscribe to:
Posts (Atom)